Thermocouple Input Module

              I-7011

         I-7011D

 
Analog Input
Type:  mV, V ,  mA (requires optional external 125 ohm resistor)
Thermocouple: Type J, K, T, E, R, S, B, N, C
Channels: 1 
Voltage range: +/-15mV, +/-50mV, +/-100mV,+/- 500mV , +/-1V,+/- 2.5V
Current range:  +/- 20mA 
Resolution: 16-bit
Sampling rate: 10 Samples/Second 
Bandwidth: 5.4 Hz 
Input impedance: 20M ohms 
Accuracy: 0.05% 
Zero Drift:  0.5uV/C
Span Drift: 25ppm/C
CMR @ 50/60 Hz: 150 dB 
NMR @ 50/60 Hz: 100 dB 
Over voltage protection:10V (P-P)
Isolation: 3000Vrms
Digital Input 
Channel: 1 
Logic Level 0: + 1V max 
Logic Level 1: + 3.5V to 30V
Event Counter
Max Input Frequency: 50Hz
Min. Pulse Width:1 ms
Digital Output
Channels: 2 
Open collector to 30V
Output Load: sink 30mA max.
Power dissipation: 300mW           
Display LED 
4 1/2 digits (for I-7011D)
Communication Interface
RS-485 
Power Supply 
Input: +10 to +30 Vdc
Consumption:
0.9W for I-7011
1.5W for I-7011D

 

Thermocouple type : (C)  
Type  Range (C)
J -210~ +760
K -270~+1372
T -270~+400
E -270~+1000
R 0~+1768
S 0~+1768
B 0~+1820
N -270~1300
C 0~2320

 

Manual